Maintenance Windows @cs.kuleuven.be
Text in red is yet to be implemented or further elaborated.
Machines in a maintenance window schema are not rebooted unless on scheduled maintenance window days.
By default, machines in a maintenance window schema do also not do automatic updates ... updates are only done during the maintenance window.
As needed, machines in a maintenance window schema can be configured to:
- either keep that default option to only update during the maintenance window
- or do automatic updates as they are made available, but not reboot unless agreed upon
- or to check for available updates without actually updating (and leave it to human interpretation what to do with the available updates)
Both non-default options need special attention and/or introduce additional dependencies and are therefore probably only suited for special purpose machines:
- Especially the option to update as becomes available requires carefull thought: doing an update without doing the potentially required reboot might hinder normal operation (rather unlikely but not entirely impossible).
- Therefore machines that are configured in that way do have an additional (but rather small) chance to have to reboot in between scheduled maintenance window days.
- But they do also have the benefit of having their software updated as it becomes available in all other cases.
We do our best to keep the maintenance window as small as possible, but no guarantees can be given about how long it can take: we hope just a few minutes but if something goes wrong all odds are off.
- implementation: updates are downloaded but not installed
If critical updates and reboots are necessary in between maintenance windows, they will only be done after consultation and agreement but:
- The basic principle is: we do not allow access to known vulnerable systems for which patches exist.
- Most likely available updates are assumed more critical on public accessible servers than on intranet machines.
- implementation: on selected systems the output of apt-get -s dist-upgrade is examined
- dit werkt omdat de package informatie geupdatet wordt omdat, en is dus een extra reden voor, de updates wel al gedownload worden
So we expect, but will also give, some ad-hoc flexibility in special circumstances (zero-day vulnerabilities, but also holiday, deadlines etc.): if really, really needed, we can change the date of the next maintenance window to some, agreed upon, earlier or later date.
But do remember that in normal circumstances we will update and most probably also reboot the machines according to their designated maintenance window schedule.
There are currently 2 maintenance windows in use:
- cs_meven: the first Tuesday of the even months
- cs_muneven: the first Tuesday of the un-even months
You can check whether and if so in which maintenance window a specific machine is scheduled by:
- if the file /etc/cron.d/cs-maintenance-window exists, the machine is included in some maintenance window
- you can find which maintenance window by looking at:
- machines in cs_meven have the file: /var/log/cs-acct/cs_meven.log
- machines in cs_muneven have the file: /var/log/cs-acct/cs_muneven.log
More detailed description of how maintenance windows are implemented, is available on the internal operator documentation.